Axial exhaust fans are an essential item in the workshop space. Helps remove odors, dust and bring fresh air. The correct installation of fans helps this product promote its full use. So what is the correct installation? Please follow the article Installing axial ventilation fans of P69 Company for details!
What is a ventilation fan?
Exhaust fan is a ventilation support device, commonly used and necessary for households. The fan helps to ventilate the air form inside the house to the outside, reducing the flow of moldy, hot, stagnant air. Form there, bringing fresh, cool air from nature into the house.
Necessity of installing axial ventilation fans
The installation of a ventilation fan helps to circulate air effectively, filtering harmful air flows to the outside. The fan ensures regular filtration of stagnant, moldy air, preventing the growth of harmful bacteria
Besides, it helps to release harmful gases in the house such as gas, smoke and odors during cooking to the outside, increasing the mount of fresh oxygen in the house.
This product is also considered as a filter, preventing dust for those with allergic rhinitis
Installation of the axial ventilation fans
Installation of the axial ventilation fan consists of 10 steps
Steps 1: Determine the room to install the ventilation fan
This is very important in the process of installing a fan, because depending in the space, you can choose a fan with the right capacity and size reducing the case when buying a fan with too much storage capacity ventilation is too large but the area of the room is too small.
Step 2: Determine a suitable location when installing the exhaust fan
When determining the position of the blower, during the installation process, you should choose the center position of the room space to optimize the air circulation evenly. If the room is too large, you should increase the number of ventilators to match.
Step 3: Prepare all the necessary tools
When installing the fan face on the wall, it is essential to prepare a full set of tools and equipment, to avoid the case that during the installation process you have to find
Step 4: Install the wall-mounted exhausted fan
First, proceed tp use a drill, drill a line to fix the position of the fan. Should use a small drill
Step 5: Drill a hole in the wall and place the ventilation fan.
When drilling holes in the wall, you need to be aware of the debris failing to the floor and remember to wear eye protection to avoid dust and dirt flying into yours eyes
When installing the machine, you must out it in the correct position that has been determined in advance. Then, insert a cable connection cord through the direct-release hole at the top of the house wall.
Step 6: Mount the fan firmly in a fixed position.
In the process of performing the above operations you should note that the screw buttons connecting the fan .
Step 7: Find a suitable exit location for the pipeline.
You should find points and locations with flat terrain, not bumpy and shortest so that the ventilation duct is able to circulate air to the outside
Step 8: Attach the ventilation cover.
The process of attaching the ventilation cover depends on the exit points on the roof and the sides of the wall. If that point is on the sidewall of the tire, you should be flexible to find the point between the two wall studs
Step 9: Attach the connection wire suitable for the indoor location.
Depending on the location of the place where the ventilator is installed, you choose the location to attach the wire. Note the short length of the cord when preparing to attach and carefully read the manufacturer’s instructions.
Step 10: Install the grille
The final step to complete the exhaust fan installation is to attach the grille to the wall, plug the fan motor into an electrical outlet, and make sure it is secured with screws.
Some notes when installing axial ventilation fans
When installing a ventilation fan, there are certain notes that you need to know to install the ventilation fan correctly
1. Installation process
The design position for the industrial fan system must be solid and solid to ensure stable operation in the future. Avoid vibrations for the device, provide safety and keep the fan durable for a long time. The installation wall should have a thickness equivalent to the width of the fan. Usually for a wall of 35-45cm is the right size when installing industrial fans.
The power source for the square industrial fan system needs to be stable because their capacity is quite large. During the construction process, it is necessary to understand the technical requirements to ensure safety both during installation and during operation. Industrial fans are currently used with 2 types, 1 phase and 3 phase. For single-phase equipment, used for 220V current, 3-phase electric fan is for 380V current to ensure no short-circuit during operation
2. After installation
Regardless of the product line, there is a specifications, put the fan on a compatible power source for the device to run stably. Check the engine performance test of the product. Adjust the suction valve to the minimum value in about 2 hours. if the machine runs normally, it will gradually open the air value until the current, the stop.
Known as industrial products with long-term durability and stable operation. however, like other machines, industrial fans should take a break for 2-3 hours a day to stabilize each part, and also help lower the engine temperature. This is also help lower the engine temperature. This is also a detail that helps the life of industrial fans to be longer.
Types of current ventilation fans
Ventilation fans have many different types, each with a design and structure suitable for each space of the house. There are machines designed specifically for use in households, companies, or apartments, making it easy for users to choose the right type of ventilation fan for their needs.
The following are some of the widely used fans on the market:
1. Wall-mounted ventilation fan
Possessing a simple and compact design, it can be easily moved and installed in many different places in the house. The product has a screen to prevent external influences from affecting the fan. The fan sounds smooth, does not make annoying noises.
2. Ceiling mounted exhaust fan
With a rather unique and novel design, large operating capacity, fans are mainly installed in some places with large spaces such as companies, high-rise buildings, office areas, …
3. Industrial ventilation fan
Relatively large fan design, high operating capacity and continuous durability. Therefore, it is used in manufacturers, factories, factories, ..
4. Axial industrial ventilation fan
Designed in an axial shape, the wind is drawn in and blown out parallel to the axial direction of the fan. The machine is mainly used in livestock areas, smoke extraction of basements, ..
5. Industrial ventilation fans with legs
Has a relatively different design than the ventilation fans mentioned above. The fan has extra brackets and wheels, which is perfect for moving anywhere you want. Fans are commonly used in factories, mines, and high-rise buildings.
Contact information P69 – M&E Contractor
Address: No. 6/165C Xuan Thuy, Cau Giay District, Hanoi
Website: https://p69.com.vn/
Hotline : 02422121212 – 0965937799
Email: kd@cokhip69.com.vn
Facebook: https://www.facebook.com/p69nhathaucodien
LinkedIn: https://www.linkedin.com/in/congtyp69/
Youtube : https://www.youtube.com/channel/UCOUwCnE5iGj8iqe_ZIUM7oA